A Rapid Quantitation of Occupational Aeroallergens by Magnetic Immuno-Chromatographic Test (MICT)
Abstract
Quantitative point-of-use assay platforms for the simple, rapid and accurate detection of aeroallergens in non-laboratory settings are fundamental to investigate their aerodynamics and implement preventive interventions for aeroallergen-associated diseases. Here, we demonstrate the application of the novel assay platform Magnetic Immuno-Chromatographic Test (MICT) for the quantitation of fungal alpha-amylase in one step and with a total assay time of 30 minutes. MICT is a magnetic-based lateral flow immunoassay (LFIA) integrated into a lab-on-a-chip format and here developed with a novel built-in hook alert function. The superparamagnetic nanoparticle probes and the magnetic detection technology makes MICT superior over traditional chromophore-based LFIAs and allow a sensitivity and accuracy comparable with central laboratory immunoassays. The alpha-amylase MICT was adjusted to a dynamic range of 0.1 to 22.3 ng/mL showing an accuracy at 99.6% (%CV 9.5). The strong analytical performance of MICT in aeroallergen studies was demonstrated by spiking air sampling filters and performing air sampling trials and the results were compared with ELISA. The principal setup shows a novel, transferable and flexible approach for quantitation of various occupational allergens. The MICT offers the required functionalities to become the new versatile lab-on-a-chip tool for hazard prevention and control of occupational allergy and asthma by allowing continuous surveillance of the allergen levels in the working environment.
Full Text:
PDFReferences
Larsen, A. I. et al. Allergy Development in Adulthood: An Occupational Cohort Study of the Manufacturing of Industrial Enzymes. J. Allergy Clin. Immunol. Pract. (2020) doi:10.1016/j.jaip.2019.06.007.
Karjalainen, A., Kurppa, K., Virtanen, S., Keskinen, H. & Nordman, H. Incidence of occupational asthma by occupation and industry in Finland. Am. J. Ind. Med. (2000) doi:10.1002/(SICI)1097-0274(200005)37:5<451::AID-AJIM1>3.0.CO;2-U.
McDonald, J. C., Keynes, H. L. & Meredith, S. K. Reported incidence of occupational asthma in the United Kingdom, 1989-1997. Occup. Environ. Med. (2000) doi:10.1136/oem.57.12.823.
Cathcart, M. et al. Enzyme exposure, smoking and lung function in employees in the detergent industry over 20 years. Occup. Med. (Chic. Ill). (1997) doi:10.1093/occmed/47.8.473.
Johnsen, C. R. et al. Allergy risk in an enzyme producing plant: A retrospective follow up study. Occup. Environ. Med. (1997) doi:10.1136/oem.54.9.671.
Larsen, A. I., Johnsen, C. R., Frickmann, J. & Mikkelsen, S. Incidence of respiratory sensitisation and allergy to enzymes among employees in an enzyme producing plant and the relation to exposure and host factors. Occup. Environ. Med. (2007) doi:10.1136/oem.2005.025304.
Schweigert, M. K., Mackenzie, D. P. & Sarlo, K. Occupational asthma and allergy associated with the use of enzymes in the detergent industry - A review of the epidemiology, toxicology and methods of prevention. Clinical and Experimental Allergy (2000) doi:10.1046/j.1365-2222.2000.00893.x.
Cullinan, P. et al. An outbreak of asthma in a modern detergent factory. Lancet (2000) doi:10.1016/S0140-6736(00)03264-5.
Platts-Mills, T. A. E., Vervloet, D., Thomas, W. R., Aalberse, R. C. & Chapman, M. D. Indoor allergens and asthma: Report of the Third International Workshop. J. Allergy Clin. Immunol. (1997) doi:10.1016/S0091-6749(97)70292-6.
Custovic, A. & Simpson, A. The role of inhalant allergens in allergic airways disease. Journal of Investigational Allergology and Clinical Immunology (2012).
Larsen, A. I. et al. Allergy Development in Adulthood: An Occupational Cohort Study of the Manufacturing of Industrial Enzymes. J. Allergy Clin. Immunol. Pract. (2019) doi:10.1016/j.jaip.2019.06.007.
Sarlo, K. Control of occupational asthma and allergy in the detergent industry. in Annals of Allergy, Asthma and Immunology (2003). doi:10.1016/S1081-1206(10)61646-8.
Raulf, M. et al. Monitoring of occupational and environmental aeroallergens - EAACI Position Paper. Allergy (2014) doi:10.1111/all.12456.
Urusov, Zherdev & Dzantiev. Towards Lateral Flow Quantitative Assays: Detection Approaches. Biosensors (2019) doi:10.3390/bios9030089.
Sajid, M., Kawde, A. N. & Daud, M. Designs, formats and applications of lateral flow assay: A literature review. J. Saudi Chem. Soc. (2015) doi:10.1016/j.jscs.2014.09.001.
Connolly, R. & O’ Kennedy, R. Magnetic lateral flow immunoassay test strip development – Considerations for proof of concept evaluation. Methods (2017) doi:10.1016/j.ymeth.2017.02.002.
O’Farrell, B. Lateral Flow Immunoassay Systems: Evolution from the Current State of the Art to the Next Generation of Highly Sensitive, Quantitative Rapid Assays. in The Immunoassay Handbook (2013). doi:10.1016/B978-0-08-097037-0.00007-5.
Workman, S. et al. Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT). J. Virol. Methods (2009) doi:10.1016/j.jviromet.2009.04.003.
Peck, R. B. et al. A magnetic immunochromatographic strip test for detection of human papillomavirus 16 E6. Clin. Chem. (2006) doi:10.1373/clinchem.2006.072884.
Hong, L. et al. High performance immunochromatographic assay for simultaneous quantitative detection of multiplex cardiac markers based on magnetic nanobeads. Theranostics (2018) doi:10.7150/thno.29070.
Moyano, A. et al. Magnetic immunochromatographic test for histamine detection in wine. Anal. Bioanal. Chem. (2019) doi:10.1007/s00216-019-02031-6.
Vanhanen, M. et al. Enzyme exposure and enzyme sensitisation in the baking
industry. Occup. Environ. Med. (1996) doi:10.1136/oem.53.10.670.
Houba, R., Van Run, P., Doekes, G., Heederik, D. & Spithoven, J. Airborne levels of α-amylase allergens in bakeries. J. Allergy Clin. Immunol. 99, 286–292 (1997).
Marraccini, P. et al. Bakery flour dust exposure causes non-allergic inflammation and enhances allergic airway inflammation in mice. Clin. Exp. Allergy (2008) doi:10.1111/j.1365-2222.2008.03038.x.
Koets, M., Sander, I., Bogdanovic, J., Doekes, G. & Amerongen, A. Van. A rapid lateral flow immunoassay for the detection of fungal alpha-amylase at the workplace. J. Environ. Monit. (2006) doi:10.1039/b605389k.
Bogdanovic, J. et al. Rapid detection of fungal α-amylase in the work environment with a lateral flow immunoassay. J. Allergy Clin. Immunol. (2006) doi:10.1016/j.jaci.2006.07.004.
Handali, S. et al. Development and evaluation of a magnetic immunochromatographic test to detect taenia solium, which causes taeniasis and neurocysticercosis in humans. Clin. Vaccine Immunol. (2010) doi:10.1128/CVI.00511-09.
Amarasiri Fernando, S. & Wilson, G. S. Studies of the ‘hook’ effect in the one-step sandwich immunoassay. J. Immunol. Methods (1992) doi:10.1016/0022-1759(92)90104-2.
Weeks, J. A., Harper, R. A., Simon, R. A. & Burdick, J. D. Assessment of sensitization risk of a laundry pre-spotter containing protease. Cutan. Ocul. Toxicol. (2011) doi:10.3109/15569527.2011.565010.
Bland, J. M. & Altman, D. G. Measuring agreement in method comparison studies. Stat. Methods Med. Res. (1999) doi:10.1177/096228029900800204.
Selby, C. Interference in immunoassay. Ann. Clin. Biochem. 36, 704–721 (1999).
Hoffman, K. L., Parsons, G. H., Allerdt, L. J., Brooks, J. M. & Miles, L. E. Elimination of ‘hook-effect’ in two-site immunoradiometric assays by kinetic rate analysis. Clin. Chem. (1984).
Flindt, M. L. Pulmonary disease due to inhalation of derivatives of Bacillus subtilis containing proteolytic enzyme. Lancet (1969) doi:10.1016/s0140-6736(69)92165-5.
Basketter, D. A. et al. Managing the Risk of Occupational Allergy in the Enzyme Detergent Industry. J. Occup. Environ. Hyg. (2015) doi:10.1080/15459624.2015.1011741.
Basketter, D., Berg, N., Kruszewski, F. H., Sarlo, K. & Concoby, B. Relevance of sensitization to occupational allergy and asthma in the detergent industry. J. Immunotoxicol. (2012) doi:10.3109/1547691X.2012.656855.
Refbacks
- There are currently no refbacks.